Dove Lifts Header
Best Elevator for a 25-Storey Building in Nigeria: The Developer Who Refused to Compromise on Performance

The architectural renderings looked impressive. A sleek, glass-fronted commercial tower rising twenty-five storeys above the Lagos skyline. For the property developer behind the project, the vision was clear: a premium office space that would attract multinational tenants and establish a new benchmark for business addresses in Ikeja. The structural engineers had signed off on the foundation design, the financing was secured, and construction was scheduled to begin within months.

Then came the elevator quotations.

Three different suppliers had submitted proposals. One offered a significantly lower price than the others. Another promised faster speeds. The third recommended a configuration with more cars but higher upfront costs. Initially, the developer focused on the bottom line. The cheapest option seemed like an easy win for the project budget. But during a review meeting, his architect asked a simple question that changed the entire conversation: "Will this system actually handle the morning rush hour for five hundred office workers?"

That question revealed a gap in the planning process. Selecting the best elevator for high rise buildings Nigeria is not merely about comparing equipment prices. It is a complex engineering decision that affects passenger waiting times, tenant satisfaction, energy consumption and long-term operational costs. This article follows the journey of a Lagos developer who learned that vertical transportation requires the same rigorous planning as the building structure itself.

Why a 25-Storey Building Needs a Properly Planned Elevator System

In low-rise buildings, elevator performance is often forgiving. A slight delay during peak hours may go unnoticed. However, in a 25-storey commercial tower, vertical transportation becomes the central artery of daily operations. The building will house hundreds of employees, clients and visitors moving between floors every day.

Morning arrival patterns create intense demand as staff rush to reach their offices before work begins. Lunch hours generate secondary peaks as people move to restaurants or leave the building. Evening departures create another surge. If the elevator system is underspecified, these peaks result in long queues in the lobby, frustrated tenants and a reputation for inefficiency.

Passenger waiting time is a critical metric. Industry standards typically aim for average waiting times of under thirty seconds during peak periods. Exceeding this threshold leads to tenant complaints and potential lease disputes. Furthermore, inefficient elevator movement increases energy consumption and wear on mechanical components. The number of floors alone cannot determine the right specification. Occupancy density, floor usage patterns and building accessibility requirements all play vital roles in defining the necessary capacity and speed.

Why Traction Elevators Are Considered for High-Rise Buildings in Nigeria

As the developer investigated his options, he learned that hydraulic elevators, common in low-rise structures, are generally unsuitable for heights beyond six or seven floors due to technical limitations. For a 25-storey building, traction elevator technology is the standard solution.

Traction elevators use an electric motor to drive a sheave, which moves steel ropes or belts attached to the elevator car and a counterweight. This system offers several advantages for high-rise applications. It provides smooth acceleration and deceleration, ensuring passenger comfort even at higher speeds. Traction systems are available in various speed configurations, allowing engineers to match performance to building height. They are also more energy-efficient than hydraulic alternatives, particularly when equipped with modern regenerative drives.

There are two main types of traction systems: geared and gearless. Geared traction uses a gearbox to connect the motor to the sheave, suitable for mid-rise applications with moderate speeds. Gearless traction connects the motor directly to the sheave, enabling higher speeds and greater efficiency for taller buildings. For a 25-storey tower, the choice between these depends on the desired speed and traffic volume. Dove Lifts, a leading elevator company in Nigeria, offers traction passenger elevators designed for such applications, with published speed ranges of 0.5–4.0 m/s and capacities from 450–2,000 kg. However, the final selection must be based on specific project calculations rather than general assumptions.

What Elevator Speed Is Suitable for a 25-Storey Building?

The developer initially assumed that faster was always better. He considered specifying the maximum available speed to minimise travel time. His elevator consultant corrected this misconception. Speed is only one variable in the equation.

For a 25-storey building, the total travel distance is approximately 75 to 80 metres, assuming standard floor heights. An elevator travelling at 2.5 m/s would take roughly 30 seconds to reach the top floor, excluding acceleration, deceleration and door operations. Increasing the speed to 4.0 m/s reduces this time, but the marginal gain may not justify the significant increase in cost and energy usage.

More importantly, speed does not solve congestion if the number of elevators is insufficient. If ten people are waiting in the lobby and only one car arrives every two minutes, the speed of that car is irrelevant to their wait time. The consultant explained that elevator speed must be balanced with capacity and frequency. Dove Lifts’ traction systems offer speeds up to 4.0 m/s, which is suitable for many high-rise projects in Nigeria. However, the optimal speed depends on the building’s specific traffic profile. A building with heavy inter-floor traffic may benefit from moderate speeds with more frequent stops, while a building with mostly lobby-to-office traffic may prioritise higher speeds.

How Much Passenger Capacity Does a High-Rise Elevator Need?

Capacity is measured in kilograms or number of persons. Standard passenger elevators range from 450 kg (approximately 6 persons) to 2,000 kg (approximately 26 persons). For a commercial office tower, larger capacities are generally preferred to reduce the number of trips required during peak hours.

The developer needed to estimate the building’s population. If each of the 25 floors housed 20 employees, the total population would be 500 people. Assuming a peak arrival rate of 12% per five minutes, sixty people would need to be transported from the lobby to upper floors in that window. A single 1,000 kg elevator (13 persons) would require five trips to move this group, taking considerable time. Multiple elevators with adequate capacity are essential to distribute this load.

Accessibility requirements also influence capacity choices. Elevators must accommodate wheelchairs, stretchers in emergency situations and large groups. Dove Lifts offers traction elevators with capacities up to 2,000 kg, providing flexibility for high-traffic commercial environments. However, selecting the largest possible capacity is not always optimal. Larger cars require larger shafts, reducing rentable floor area. The goal is to find the balance between passenger throughput and spatial efficiency.

How Many Elevators Should a 25-Storey Commercial Building Have?

This question caused the most debate in the developer’s project meetings. Some suggested two elevators to save space. Others recommended four to ensure rapid service. The answer lies in professional traffic analysis.

Traffic analysis models simulate passenger movement based on building occupancy, floor distribution and arrival patterns. These models calculate key metrics such as average waiting time, handling capacity and interval time. For a 25-storey office building, a typical configuration might include three to four passenger elevators grouped together. This allows for efficient dispatching, where the control system assigns the nearest available car to a call.

Consider two hypothetical buildings. Building A has 25 floors with low-density executive offices, housing 100 people total. Building B has 25 floors with open-plan co-working spaces, housing 600 people. Building A might operate efficiently with two elevators. Building B would likely require four or five to maintain acceptable waiting times. This illustrates why floor count alone is an inadequate predictor of elevator needs. Developers must conduct a traffic study based on their specific tenant mix and usage expectations.

Why the Elevator Control System Matters as Much as Speed

The developer discovered that hardware specifications tell only half the story. The control system determines how efficiently the elevators operate. Modern traction elevators use microprocessor-based controls and Variable Voltage Variable Frequency (VVVF) drives.

VVVF technology adjusts the power supplied to the motor, enabling smooth starts and stops. This reduces mechanical stress and improves energy efficiency. Microprocessor controls manage complex logic, such as grouping multiple elevators to serve different zones or prioritising certain floors. For example, during morning peaks, the system might dedicate one elevator to express service for upper floors while others serve lower levels.

Dove Lifts incorporates VVVF drive technology and advanced microprocessor controls in its traction passenger elevator systems. These features ensure precise floor levelling, reducing the gap between the car and the landing, which enhances safety and accessibility. Efficient control systems also reduce unnecessary stops, shortening journey times and improving passenger experience. Without sophisticated control logic, even fast elevators can become bottlenecks due to poor dispatching.

What Safety Features Should Developers Check Before Buying a High-Rise Elevator?

Safety is non-negotiable in high-rise elevator design. The developer reviewed the safety specifications provided by suppliers, focusing on critical protection systems. Key features include overspeed governors, which detect excessive speed and trigger safety gears to stop the car. Door interlocks prevent the elevator from moving if doors are not fully closed. Emergency communication systems allow passengers to contact building management or emergency services if trapped.

Compliance with international standards such as EN 81 and ASME A17.1 is a baseline requirement. However, developers must also ensure compliance with Nigerian regulatory requirements. Local authorities may have specific inspection and certification processes. Dove Lifts designs its traction elevators to meet EN 81 and ASME A17.1 standards, providing a robust framework for safety. Developers should request documentation proving compliance and insist on thorough testing and commissioning before handover. Regular maintenance contracts are also essential to keep safety systems functional over the building’s lifecycle.

What Should a Developer Consider Beyond the Elevator Purchase Price?

The initial quotation tempted the developer with its low price. However, his consultant highlighted hidden costs. Installation complexity, shaft preparation, electrical infrastructure and ongoing maintenance contribute significantly to the total cost of ownership.

A cheaper elevator may require more frequent repairs, leading to higher downtime and tenant dissatisfaction. Spare parts availability is crucial. If a component fails and replacements must be imported, the elevator could be out of service for weeks. Local support networks mitigate this risk. Dove Lifts maintains a presence in Nigeria, with an office in Ikeja, Lagos, offering local technical support and spare parts supply.

Lifecycle operating costs include energy consumption, which varies with drive technology and usage patterns. Preventive maintenance contracts ensure regular inspections and adjustments, extending equipment life. Developers should evaluate quotations based on total lifecycle cost, not just initial purchase price. A slightly more expensive system with lower maintenance needs and higher reliability often delivers better long-term value.

How Should Developers Evaluate Elevator Companies in Nigeria?

To make an informed decision, the developer created a supplier evaluation checklist. He assessed each company against the following criteria:

Selection factorWhat the developer should assessWhy it matters
SpeedTravel distance, floors and trafficJourney time and passenger movement
CapacityPassenger load and occupancyAvoiding unsuitable loading arrangements
Number of elevatorsTraffic analysis and building populationWaiting times and service availability
Control systemDispatching and group controlEfficient passenger movement
SafetyProtection systems and compliancePassenger protection and regulatory obligations
MaintenanceService availability and spare partsLong-term reliability

Beyond technical specifications, he evaluated the companies’ project experience. Had they installed elevators in similar high-rise buildings in Nigeria? Did they have qualified engineers for installation and commissioning? Were their warranty terms clear and comprehensive? Responsiveness during the quotation phase indicated their level of customer service.

Dove Lifts demonstrated an engineering-led approach, offering consultation, site assessment, technical design, installation, testing and ongoing maintenance. Their team explained the rationale behind their recommendations, providing transparency that built trust. For developers seeking a reliable partner for high rise elevator Nigeria projects, such technical clarity is invaluable.

Why the Developer Chose to Plan for Performance, Not Just Purchase Price

The Lagos developer ultimately rejected the cheapest quotation. He chose a configuration recommended by his consultant, featuring three traction elevators with VVVF drives and microprocessor controls, sourced from a provider with strong local support. This decision was based on traffic analysis, safety compliance and long-term operational efficiency.

His experience highlights a crucial lesson for property developers in Nigeria. Choosing the best elevator for high rise buildings Nigeria requires a holistic view of the building’s operational needs. It involves balancing speed, capacity, control technology and maintenance support. It demands professional traffic analysis and adherence to safety standards. And it requires a partner who understands the local context and technical requirements.

For developers planning 25-storey towers or other high-rise commercial projects in Lagos, Abuja or Port Harcourt, engaging with experienced elevator specialists early in the design phase is essential. Dove Lifts offers the technical expertise and product range to support such ambitious projects. From initial consultation to ongoing maintenance, their team ensures that vertical transportation enhances rather than hinders building performance.

If you are planning a high-rise development, do not leave elevator selection to chance. Contact Dove Lifts today to discuss your project requirements. Share your building location, floor count, expected occupancy and timeline. Their engineering team will provide a tailored assessment and recommendation, ensuring your building rises to the occasion.

Frequently Asked Questions

1. What is the best elevator for a 25-storey building in Nigeria? The best elevator depends on traffic analysis, but traction elevators with speeds between 2.0–4.0 m/s and capacities of 1,000–2,000 kg are commonly suitable for 25-storey commercial buildings. Professional assessment is required for specific projects.

2. Are traction elevators suitable for high-rise buildings? Yes, traction elevators are the standard for high-rise buildings due to their ability to achieve higher speeds, greater efficiency and smoother ride quality compared to hydraulic systems.

3. What elevator speed is suitable for a 25-storey building? Speeds between 2.5 m/s and 4.0 m/s are typical for 25-storey buildings. The exact speed depends on travel distance, traffic volume and desired journey times.

4. How many elevators does a 25-storey commercial building need? Typically, three to four elevators are required, but this varies based on occupancy density and traffic patterns. A professional traffic analysis is necessary to determine the optimal number.

5. What elevator capacity is suitable for a high-rise office building? Capacities between 1,000 kg and 2,000 kg are common for commercial high-rises. Higher capacities reduce the number of trips needed during peak hours.

6. What is the difference between traction and MRL elevators? MRL (Machine Room-Less) is a configuration where the machine is located in the shaft, saving space. Traction refers to the drive technology. MRL elevators can use traction technology, but traditional traction elevators may have a separate machine room.

7. How much does it cost to install an elevator in a 25-storey building in Nigeria? Costs vary widely based on specifications, number of units, brand and installation complexity. Developers should request detailed quotations from multiple suppliers for accurate budgeting.

8. Why should developers conduct an elevator traffic analysis? Traffic analysis predicts passenger flow and waiting times, ensuring the elevator system meets demand. It prevents under-specification, which leads to congestion, and over-specification, which wastes resources.

9. What safety standards should a high-rise elevator meet? Elevators should comply with international standards like EN 81 or ASME A17.1, as well as local Nigerian regulatory requirements. Compliance ensures passenger safety and legal operation.

10. How can I get a quotation for a high-rise elevator project in Nigeria? Contact elevator suppliers like Dove Lifts with your project details, including drawings, floor count and occupancy estimates. They will conduct an assessment and provide a tailored quotation.

Leave a Reply

Your email address will not be published. Required fields are marked *